Water Watch - Electronic Urinal Flush Control Systems

HOW YOU CAN SAVE £400 A YEAR

Water Saving Assumptions:

Water Watch - Urinal Flush Control - Predicted Water ConsumptionMANUAL SYSTEM
Three urinals are fed by a 9 litre cistern and the water flow rate has been adjusted so that the system flushes every 20 minutes.

WATER WATCH CONTROL SYSTEM
the cistern is controlled by an electrical solenoid valve which is automatically opened for a pre-set period every 20 minutes.  A PIR presence detector ensures that the system does not flush if the washroom is unoccupied.

Water consumption:

The toilets are assumed to be available for 9 hrs/day, 6 days/week and 52 weeks /annum.  They will not be continuously occupied and a utilisation factor of 60% is used to allow for unoccupied periods longer than 20 minutes.

Manual system - 20 minute flush, 24 hrs/day, 365 days/year

 

Annual flushes 

= 26,280

 

Consumption @ 9 litres/flush

= 236.5 m3

Water Watch - 20 minute flush during occupancy

 

Available  occupancy period

= 9hrs/day, 6days/wk, 52wks/ann
= 2,808/ann

 

Annual flushes (continuous occupancy) @ 60 % occupancy factor

= 8,424
= 5,054

 

Consumption

= 45.5 m3

 

Water Saving 

= 191m3

 

COST SAVING @ £2.079 p/m3 *

= £397 p.a.

*  based on United Utilities tariff for commercial building - water charge 121.8 p/m3, sewage charge 86.1 p/m3.





Mesh Communications Limited
21 Ashwood
Bowdon
Altrincham
Cheshire
WA14 3DN

Phone: 0161 929 7844
(Outside UK) +44 161 929 7844
Fax: 0870 005 2772
Email:

 

2008 © Copyright Terry Dudley